Female patient 46 yo with trouble of urine discharge for 1 month.
She wore her IUD for 8 years but could not find it out 4 years before in giving up this contraception measure.
Transabdominal ultrasound and TVS revealed a metallic foreign body in her bladder with strong color comet tail artifact.
And later MSCT confirmed the T- shape IUD which penetrated to urinary bladder and was coated outside surface of it in formation of stone.
Endoscopic surgery successfully performed on March 15 to remove the stone made T- shape IUD in TD hospital.
Endoscopy in surgery showed stone in urinary bladder.
Specimen of the T-shape IUD with stone covered on part, and another broken branch was in uterine muscle that adhered urinary bladder.
CONCLUSIONS:
Migration of T-shape IUD has highly risk of penetration the hollow organes like rectum, urinary bladder. Ultrasound may help to detect the ectopic T-shape IUD but it needs obviously using other diagnostic imaging modalities, endoscopic tools to confirm the status and location of it for appropriate management to the patient.
REFERENCE
CASE 514 VUD
No comments:
Post a Comment