Female patient 46 yo with trouble of urine discharge for 1 month.
She wore her IUD for 8 years but could not find it out 4 years before in giving up this contraception measure.
Transabdominal ultrasound and TVS revealed a metallic foreign body in her bladder with strong color comet tail artifact.
And later MSCT confirmed the T- shape IUD which penetrated to urinary bladder and was coated outside surface of it in formation of stone.
Endoscopic surgery successfully performed on March 15 to remove the stone made T- shape IUD in TD hospital.
Endoscopy in surgery showed stone in urinary bladder.
Specimen of the T-shape IUD with stone covered on part, and another broken branch was in uterine muscle that adhered urinary bladder.
CONCLUSIONS:
Migration of T-shape IUD has highly risk of penetration the hollow organes like rectum, urinary bladder. Ultrasound may help to detect the ectopic T-shape IUD but it needs obviously using other diagnostic imaging modalities, endoscopic tools to confirm the status and location of it for appropriate management to the patient.