Man 52 yo with pain
in liver and history of treating liver abscess by ultrasound guided puncture and drainage for 1
month..
Ultrasound
scanning with linear probe=
US 1:detecting liver
abscess in recovery phase with one echo rich foreign body came from duodenum. in
the boder of liver.
US 2: CDI
no change of vascular structure of liver.
US 3 : elastoscan
showed this body having very red
code whicn means very hard.
CT liver
scanning also detected foreign body ( fb) intra liver and one site was
intra duodenum wall.
Emergency
endoscopy cannot detect this fb.
Laparoscopy
removed the fish bone with length of3.5 cm (photo).